Two real constraints in an underground car park are humidity and exhaust: humidity rusts a non-sealed fixture within two years, and sulphur compounds in the exhaust blacken the plating. The one that gets missed is impact — clear heights are low and deliveries hit the fixtures, so IK08 is the practical floor here.

[Get a Quote](https://wa.me/8613809877696)

## Key parameters

| Power | 18–40 W |
| --- | --- |
| Luminous flux | 2,300–5,200 lm |
| IP rating | IP65 |
| Impact rating | IK08 |
| Operating temperature | -5 … +40 ℃ |

[Product family: Tri-Proof Lights](https://www.xingguanglightingcn.com/en/product-categories/tri-proof)

## Environment is not only about water

What actually kills fixtures on site, in order of how often it happens: ① heat — every 10 ℃ of chamber temperature roughly halves driver life; ② corrosive gas or salt fog — it eats the screws and the coating first and enters through the seam afterwards; ③ dust — it blocks the fins, which is heat again; ④ cold — capacitors struggle to start and plastics go brittle. IP covers only the water part.

So the order of questions should be: what is the ambient temperature, is there a corrosive medium, how is dust cleaned, what is the minimum temperature — and IP last. Reverse the order and the fixtures start failing three months in, with a perfectly adequate [IP rating](https://www.xingguanglightingcn.com/en/glossary#ip-rating).

## How to check the temperature item

This page is rated -5 … +40 ℃. Note that this is the **ambient temperature the fixture tolerates**, not the body temperature — the two differ by the temperature rise. What the driver sees is ambient plus rise, and the rise comes from heatsink area: same wattage, different construction, 20 ℃ apart.

The check is simple: ask for the driver model, then read its derating curve at the actual chamber temperature. A quote that cannot produce that curve has not answered the temperature question, whatever the ℃ figure says.

## Four things to verify before ordering

① Whether flux and [efficacy](https://www.xingguanglightingcn.com/en/glossary#efficacy) are quoted for the complete fixture or the light source — a 10–15% difference that changes the fixture count. ② Whether [colour temperature](https://www.xingguanglightingcn.com/en/glossary#cct) and CRI are measured or nominal values; mixed CCT within one batch is the most common arrival dispute. ③ Driver brand and model, plus its derating curve at high temperature — it is the only part that really sets life. ④ The mounting kit list: chain, bracket and anchors in the box, or the site stops for a day.

## Concepts on this page

[Tri-proof light](https://www.xingguanglightingcn.com/en/glossary#tri-proof)[IP rating](https://www.xingguanglightingcn.com/en/glossary#ip-rating)[Impact resistance](https://www.xingguanglightingcn.com/en/glossary#ik-rating)

![Tri-Proof Light TP-101](https://www.xingguanglightingcn.com/assets/img/prod-tp101.webp)

### [Tri-Proof Light TP-101](https://www.xingguanglightingcn.com/en/products/tri-proof-101)

Tri-proof

## Need a Lighting Plan?

Tell us your scenario, Jie Zhai will help you choose.

[Get a Quote](https://wa.me/8613809877696)
[All specification pages](https://www.xingguanglightingcn.com/en/spec/)