title: "Xingguang | 100W High Bay Lights | LED Lighting"
description: "100 W is the starting point for low-bay workshops: packaging, assembly and small-parts storage at 5–8 m and 200–300 lx. One bay higher and you need 150 W to hold uniformity."
url: "https://www.xingguanglightingcn.com/en/spec/high-bay-100w"
lang: "en"
updated: "2026-10-28"
markdown: "https://www.xingguanglightingcn.com/en/spec/high-bay-100w.md"
---

[Home](https://www.xingguanglightingcn.com/en/) / [Selection by specification](https://www.xingguanglightingcn.com/en/spec/) / 100W High Bay Lights

# 100W High Bay Lights

100 W is the starting point for low-bay workshops: packaging, assembly and small-parts storage at 5–8 m and 200–300 lx. One bay higher and you need 150 W to hold uniformity.

[Get a Quote](https://wa.me/8613809877696)

## [Key parameters](https://www.xingguanglightingcn.com/en/glossary#efficacy)

| Power | 100 W |
| --- | --- |
| Efficacy | 130 lm/W |
| Luminous flux | 13,000 lm |
| Maintained flux | 9,100 lm |
| Mounting height | 5–8 m |
| Coverage per fixture | 40–60 m² |
| Design illuminance | 200–300 lx |
| HID equivalent | 250 W |

[Product family: High Bay Lights](https://www.xingguanglightingcn.com/en/product-categories/high-bay)

## What the wattage figure does not tell you

At 130 lm/W, 100 W gives about 13,000 lm at the fixture; applying a 0.7 maintenance factor, roughly 9,100 lm reaches the floor at end of life. Layout counts come from 9,100 lm, not from the nameplate 100 W — layout by wattage and the far row always ends up dim.

A second double count: the 130 lm/W figure already includes driver losses. Discounting again by driver efficiency deducts the same loss twice and over-counts fixtures.

## The height and area it actually covers

At 5–8 m and a design illuminance of 200–300 lx, one 100 W fixture covers about 40–60 m². That range is back-calculated from the maintained 9,100 lm, not the initial output — lay out on initial [lumens](https://www.xingguanglightingcn.com/en/glossary#lumen) and the site is under-lit well before the first relamping cycle.

If the existing HID is 250 W, 100 W lands in the same bracket: comparable flux, roughly a third of the power draw, and the circuit and switchgear usually carry over. What to re-check is inrush current and the earth-leakage setting.

## Four things to verify before ordering

① Whether flux and efficacy are quoted for the complete fixture or the light source — a 10–15% difference that changes the fixture count. ② Whether colour temperature and CRI are measured or nominal values; mixed CCT within one batch is the most common arrival dispute. ③ Driver brand and model, plus its derating curve at high temperature — it is the only part that really sets life. ④ The mounting kit list: chain, bracket and anchors in the box, or the site stops for a day.

## Concepts on this page

[High bay](https://www.xingguanglightingcn.com/en/glossary#high-bay)[Lumen](https://www.xingguanglightingcn.com/en/glossary#lumen)[Illuminance](https://www.xingguanglightingcn.com/en/glossary#illuminance)

![LED High Bay HBL-036](https://www.xingguanglightingcn.com/assets/img/prod-hbl036.webp)

### [LED High Bay HBL-036](https://www.xingguanglightingcn.com/en/products/high-bay-light-036)

150W

## Need a Lighting Plan?

Tell us your scenario, Jie Zhai will help you choose.

[Get a Quote](https://wa.me/8613809877696)
[All specification pages](https://www.xingguanglightingcn.com/en/spec/)